Refurbishment · Somerset
TR Autos, Yeovil
A worn asbestos cement roof stripped and replaced with Tata Trisomet composite panels, with new insulated gutters ending years of overflowing and leaks.
- Programme
- Two weeks
- Roof
- c. 400 m²
- Completed
- 2026
The project
An industrial building on a steel portal frame, with a profiled asbestos cement roof that had reached the end of its serviceable life.
The roof and gutters were badly deteriorated, with water getting in and gutters failing. The owner came back to us after we delivered their project at Tapstone Road, Chard. The roof was beyond economical repair, so we advised a full strip and replace.
Over two weeks we replaced the roof with Tata Trisomet 333 composite panels, renewed the boundary wall gutter with new insulated gutters and linings, and insulated the parapet walls and cappings.
- Strip and ReplaceAsbestos cement roof replaced with 120mm composite panels.
- New GuttersLarger insulated gutters with Plygene linings, easy to access.
- Two WeeksRoof, gutters and parapets completed in a two-week programme.

Scope and specification
- Roof
- c. 400 m²
strip and replace - Roof system
- Tata Trisomet 333
120mm composite - Finish
- Goosewing Grey
HPS200 Ultra - Gutter linings
- Plygene
by HD Sharman
- New insulated boundary wall and valley gutters
- Insulated parapet walls and cappings
- Stainless steel fixings, flashings and finishing details
- External scaffolding and safety netting

The challenge
Replacing the gutters in a day
The new gutters are larger than the originals, so the old gutters had to be taken out and the new ones fitted within a single day.
To make room for them, the team removed the eaves line purlins, cut off the purlin cleats, fixed new cleats to the structural steel frame, then refitted and aligned the purlins. It was tough going for the team.
Surveying an old building and redesigning the roof around it took care too. Everything fitted correctly, without issue.
Before
The original roof
A profiled asbestos cement roof at the end of its life, with failing gutters.



The result
A big transformation
The building was uninsulated and had always suffered from overflowing gutters and a failing roof. Its thermal efficiency is now up to modern standards, the new panels are bright inside, and the long-standing gutter problems are solved with larger, easy-to-access gutters.
The tenant was very impressed with the upgrade and the difference it has made to their working premises.
Discuss a similar project
Completed
The finished roof



Accredited, approved and audited
Get in touch
Request a survey
Working on something similar? Send us the building, the problem and the programme. We survey, price and deliver.